Parabolic Trough Mirror2022-06-17T02:29:33+00:00
parabolic trough mirror

Parabolic trough mirror for CSP and STE heat utilization

  • 1.Glass

  • 2. Silver

  • 3. Copper

  • 4. Paint

Parameters

Model Size(mm) Aperture(mm) Focal Length(mm) Application
RP3 Inner 1700*1641*4 5774 1710 CSP
Outer 1700*1501*4
RP5A Inner 1733*2010*4 7400 2000
Outer 1733*2010*4
RP6 Inner 1800*1600*4 8600 2300
Middle 1800*1600*4
Outer 1800*1565*4
RC4 1463*1356*4 2550 850 STE
RC3A 1463*1583.75*4 3000 950
Technical Parameter Requirement Remark
av. reflecticity ≥94% Air quality AM1.5, wavelength 300~2500mm
av. FDx ≤6.9mm QDEC test data
IC70 (laser) ≥99.95% QDEC test data
Anti-aging DLRPSA tests passed
Life cycle >25 years

Parameter Interpretation

  • SDx: square root of the true deviation slope of the reflected light in the X direction (through the collector axis) compared with the slope of the ideal mirror surface, in mrad
  • SDy: square value of the true deviation slope of the reflected light in the Y direction (along the direction of the heat collector) and the slope of the ideal mirror surface
  • FDx: square value of the true focus deviation of the reflected light in the X direction (through the axis of the collector tube) compared with the ideal collector parabolic focal line, in mm
  • FDy: square value of the true focus deviation of the reflected light in the Y direction (along the direction of the collector tube) and the ideal collector parabolic focal line, in mm

Surface Error Comparison

常见问题FAQ

Where can I use parabolic trough system?2022-04-19T11:43:33+00:00

Solar thermal power plants, urban heating, steam utilization, seawater desalination, etc.

What’s the life cycle of trough mirros2022-04-19T11:40:22+00:00

Generally if they are properly used, they can serve 25~30 years.

Do you have warranty for parabolic trough mirrors2022-04-19T11:37:48+00:00

Yes, our warranty is five years.